CFD Consulting for MEP Firms

CFD Analysis Services

Practical HVAC CFD studies scoped to address your specific design question — from air distribution and thermal comfort to contaminant control and exhaust performance.

01 — HVAC CFD Analysis

Air Distribution CFD

Evaluate supply air throw, stratification, short-circuiting, stagnant zones, diffuser performance, return/exhaust placement, and high-ceiling space air movement.

  • Supply air throw and diffuser jet behaviour
  • Thermal stratification and layering assessment
  • Short-circuiting between supply and return/exhaust
  • Identification of stagnant or poorly ventilated zones
  • High-ceiling and atrium air movement
  • Return and exhaust placement optimisation
Room CFD temperature and airflow visualization
CFD OutputVelocity / Temperature
02 — Thermal Comfort Analysis

Thermal Comfort Studies

Assess occupant comfort using temperature gradients, velocity distribution, draft risk, radiant effects where applicable, and project-specific comfort targets.

  • Temperature gradient mapping across occupied zones
  • Velocity distribution and draught risk assessment
  • PMV/PPD comfort index evaluation
  • Operating temperature analysis
  • Asymmetric radiant temperature effects
  • Project-specific comfort performance criteria
Office workstation CFD simulation
CFD OutputVelocity / Temperature
03 — Ventilation Effectiveness & Age of Air Analysis

Age of Air & Air Change Effectiveness

Analyze ventilation effectiveness, fresh air distribution, local mean age of air, air change effectiveness, and areas with poor ventilation performance.

  • Local mean age of air mapping
  • Air change effectiveness evaluation
  • Fresh air distribution across occupied zones
  • Identification of poorly ventilated areas
  • Ventilation effectiveness benchmarking
  • Support with ventilation design criteria
Multi-level CFD airflow and thermal simulation
CFD OutputAge of Air / Temperature
04 — Contaminant Control CFD

Pathogen / Contaminant Control

Model airflow patterns, contaminant transport, dilution, directional airflow, exhaust capture, and containment strategies for healthcare, laboratory, institutional, and high-occupancy spaces.

  • Contaminant transport and dilution modelling
  • Directional airflow and pressure relationship assessment
  • Exhaust capture and containment effectiveness
  • Healthcare and isolation room airflow studies
  • Laboratory and containment room analysis
  • High-occupancy space ventilation strategies
Healthcare patient room CFD temperature analysis
CFD OutputContainment / Comfort
05 — Exhaust Capture Analysis

Exhaust & Capture Performance

Review exhaust placement, capture effectiveness, make-up air interaction, cross-contamination risk, and airflow paths for specialized rooms and process exhaust applications.

  • Exhaust hood and grille placement optimisation
  • Capture effectiveness under varying airflow conditions
  • Make-up air supply and interaction with exhaust
  • Cross-contamination risk assessment
  • Airflow path and short-circuit analysis
  • Process exhaust and specialty application studies
Exhaust performance CFD visualization
CFD OutputVelocity / Exhaust
06 — HVAC Design Comparison CFD

Design Option Comparison

Compare multiple HVAC layouts, diffuser selections, supply temperatures, airflows, or exhaust strategies to support design decisions.

  • Side-by-side comparison of HVAC layout options
  • Diffuser type and placement evaluation
  • Supply air temperature and flow rate optimisation
  • Exhaust strategy comparison
  • Ranked performance against comfort and ventilation criteria
  • Design decision support documentation
Design comparison CFD visualization
CFD OutputOption Comparison

Need CFD support for a specific HVAC design question?

Send your drawings, airflow criteria, and the question the model needs to answer. We will review the scope and recommend an appropriate CFD approach.

Request a CFD Review